Kanomax Multi-Channel Anemometers are research-grade airflow measuring instruments designed for high performance and precision. When coupled with our highly accurate probes this four-channel anemometer provides highly accurate and reliable data readings. It features a LCD display that displays the data from each channel. The Our 1550 & 1560 models house module bays for the connection of up to 24 channels (model 1560) or 64 channels (model 1550) of simultaneous air velocity measurements. Each bay accepts one of five unique modules allowing for a wide variety of custom configurations for air velocity, temperature, and humidity measurement. For a larger system, you can connect up to 5 units in a cascade for up to 320 air velocity channels and transfer the data to your company computer.
Navigate the tab section below to see this product’s Features & Benefits, Specifications, Resources, and more.
Main Unit Specifications | ||
---|---|---|
Model | 1550 | 1560 |
Display Resolution | 0.01 m/s (@ range of 0 to 9.99m/s) 0.1 m/s (@ 10 m/s or more) 0.1°C (Temperature) 0.1% (Relative Humidity) |
|
Number of Module Slots | 16 | 6 |
Analog Output | 0 to 5 V (with optional module) | |
Interface | RS-232C | |
Operation Temperature | 41 to 104°F (5 to 40°C) with no condensation | |
Storage Temperature Range | 14 to 122°F (-10 to 50°C) with no condensation | |
Dimensions | 16.9″ x 19.6″ x 5.5″ (430 x 500 x 140 mm) | 8.9″ x 12.8″ x 5.5″ (226 x 325 x 140mm) |
Weight | 22lbs (10kg) | 11lbs (5kg) |
Power | AC 100V (50/60 Hz) | |
Warranty | 1 year | |
Standard Accessory | Meter, Operation Manual, RS-232C Cable, Power Cord, Fuse |
Optional Probe Specifications | |
---|---|
Air Velocity | |
Ranges | 0.1 to 25.0 m/s 0.1 to 50.0 m/s |
Accuracy | +/- (3% of READING +/- 0.1) m/s |
Operating Temperature Range | -4 to 158°F (-20 to 70°C) with no condensation |
Storage Temperature Range | 14 to 122°F (-10 to 50°C) with no condensation |
Warranty | 1 year |
Standard Accessory | Probe, Data ROM, NIST Certificate |
Model | 0962-00 | 0963-00 | 0965-00 | 0965-01 | 0965-03 | 0965-04 | 0965-07 | 0965-08 | 0965-09 | 0965-10 |
---|---|---|---|---|---|---|---|---|---|---|
Air Velocity Range (m/s) | 0.1 to 50.0 | 0.1 to 50.0 | 0.1 to 25.0 | 0.1 to 25.0 | 0.1 to 25.0 | 0.1 to 25.0 | 0.1 to 25.0 | 0.1 to 25.0 | 0.1 to 50.0 | 0.1 to 50.0 |
Airflow Directivity | Mono | Mono | Omni | Omni | Omni | Omni | Omni | Omni | Omni | Omni |
Probe Type | Rod | Rod | Spherical | Spherical | Miniature | Miniature | Miniature | Miniature | Spherical | Spherical |
Air Velocity | O | O | O | O | O | O | O | O | O | O |
Acclimation Time (sec) | 1 | 1 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 |
Air Velocity | |
---|---|
Ranges | 0.1 to 25.0 m/s 0.1 to 50.0 m/s |
Accuracy | +/- (3% of READING +/- 0.1) m/s |
Temperature | |
Ranges | 0 to 100 °C |
Accuracy | +/- 1 °C |
Operating Temperature Range | -4 to 158°F (-20 to 70°C) with no condensation |
Storage Temperature Range | 14 to 122°F (-10 to 50°C) with no condensation |
Warranty | 1 year |
Standard Accessory | Probe, Data ROM, NIST Certificate |
Model | 0962-21 | 0963-21 | 0965-21 |
---|---|---|---|
Air Velocity Range (m/s) | 0.1 to 50.0 | 0.1 to 50.0 | 0.1 to 25.0 |
Airflow Directivity | Mono | Mono | Omni |
Probe Type | Rod | Rod | Spherical |
Air Velocity | O | O | O |
Air Temperature | O | O | O |
Acclimation time (sec) | 1 | 1 | 7 |
Air Velocity | |
---|---|
Ranges | 0.1 to 25.0 m/s 0.1 to 50.0 m/s |
Accuracy | +/- (3% of READING +/- 0.1) m/s |
Temperature | |
Ranges | 0 to 60 °C |
Accuracy | +/- 1 °C |
Relative Humidity | |
Ranges | 5 to 95 %RH |
Accuracy | +/- 3% (@ 5 to 80%RH) +/- 5% (@ 80 to 95 %RH) |
Operating Temperature Range | -4 to 158°F (-20 to 70°C) with no condensation |
Storage Temperature Range | 14 to 122°F (-10 to 50°C) with no condensation |
Warranty | 1 year |
Standard Accessory | Probe, Data ROM, NIST Certificate |
Model | 0963-31 | 0965-31 |
---|---|---|
Air Velocity Range (m/s) | 0.1 to 50.0 | 0.1 to 25.0 |
Airflow Directivity | Mono | Omni |
Probe Type | Rod | Spherical |
Air Velocity | O | O |
Air Temperature | O | O |
Relative Humidity | O | O |
Acclimation time (sec) | 1 | 7 |
They measure the air speed by calculating how fast the probe sensor is being cooled by the airflow.
Yes, all our instruments come with a calibration certificate.
Annual calibration is recommended to ensure accuracy. However, this can vary based on how often the anemometer is used and the environments it’s used in. Also, some companies have an SOP in place that specifies how often the instrument will need to be serviced. More specifically, regulatory compliance may dictate the calibration interval.
You can measure clean air between -4 and 158°F (-20 to 70°C) in an environment with no visible condensation. (Please note: the temperature range given is for the probes)
No, these are thermal anemometers that generate heat when in operation; if you expose them to a flammable gas it could cause a fire or explosion. Corrosive or caustic gases, such a chlorine, will damage the sensor on contact. While it is possible to use the instrument in a non-flammable, non-caustic gases the instrument is not calibrated for these gases and it will not measure airflow accurately.
We have three multi-channel anemometers: The 1570 is a 4-channel anemometer that just measure air velocity. The 1550 and 1560 have more channels (16 and 6 respectively) and can also measure temperature and relative humidity. These two units can be operated in a cascade configuration where multiple units can be chained together to create more channels.
These systems are designed for flexibility so you can buy exactly what you need for your specific application. The 4-channel 1570 is easy to order as it requires only the main unit and then whichever probes and cables suit your application. The 1550 and 1560 are a bit more complex as these instruments are composed of the chassis, modules, cables and probes. Each probe must have the correct corresponding module installed in the chassis to plug into. We suggest calling your distributor or Kanomax to get assistance with ordering these systems.
Data processing software, RS232C cable, power cable and 2 pcs. fuse.
Give us a call! Our customer service team is happy to discuss your application and find a solution that works for you. We won’t sell you a product that doesn’t meet your needs.
Our sales representatives are here to help you find the right instrument for your application. Fast.
Request a quote today to find the product you need with expert assistance.