The Kanomax Airflow Transducer – Models 6332/6332D comes equipped with analog output and smart probe technology, making it easy to integrate with other equipment. Smart probe technology lets you change probes without recalibrating the transducer. Multiple probe options are available separately, allowing you to choose the ones that meet your application needs. This instrument is ideal for applications involving the need to measure or monitor air velocity over a long duration. Model 6332D comes with a display, while Model 6332 does not have a display.
Navigate the tab section below to see this product’s Features & Benefits, Specifications, Resources, and more.
Main Unit Specifications | ||
---|---|---|
General Specifications | ||
Analog Output | Current output: DC 4~20mA (Max. load resistance: 250Ω) Voltage output: DC 0~5V |
|
Display Resolution (Model 6332D only) | 0.01m/s (Velocity Range: 0 to 2, 0 to 5, 0 to 10 m/s) 0.1m/s (Velocity Range: 0 to 25, 0 to 50 m/s) |
|
Response Time | Display: 0.3 second Sampling: 0.1 second Output: 0.1 second | |
Power Supply | DC 12 to 24V | |
Operating Temperature Range | 41 to 104 ºF (5 to 40 ºC) with no condensation | |
Storage Temperature Range | 14 to 122°F (-10 to 50°C) with no condensation | |
Dimensions | 128(W)×78(D)×30(H) mm | |
Weight | 0.7 lbs (320g) | |
Warranty | 1 year | |
What’s Included | Meter, Operation Manual | |
Airflow Transducer Probes (See Table Below) | ||
Measurement Specifications | ||
Air Velocity | Ranges | 0.1 to 25.0 m/s 0.1 to 50.0 m/s |
Accuracy | +/- (3% of READING +/- 0.1) m/s | |
Operating Temperature Range | -4 to 158°F (-20 to 70°C) with no condensation | |
Storage Temperature Range | 14 to 122°F (-10 to 50°C) with no condensation | |
Warranty | 1 year | |
What’s Included | Probe, Data ROM, NIST TRACEABLE CALIBRATION Certificate |
Model | 0962-00 | 0963-00 | 0965-00 | 0965-01 | 0965-03 | 0965-04 | 0965-07 | 0965-08 | 0965-09 | 0965-10 |
---|---|---|---|---|---|---|---|---|---|---|
Air Velocity Range (m/s) | 0.1 to 50.0 | 0.1 to 50.0 | 0.1 to 25.0 | 0.1 to 25.0 | 0.1 to 25.0 | 0.1 to 25.0 | 0.1 to 25.0 | 0.1 to 25.0 | 0.1 to 50.0 | 0.1 to 50.0 |
Airflow Directivity | Mono | Mono | Omni | Omni | Omni | Omni | Omni | Omni | Omni | Omni |
Probe Type | Rod | Rod | Spherical | Spherical | Miniature | Miniature | Miniature | Miniature | Spherical | Spherical |
Air Velocity | O | O | O | O | O | O | O | O | O | O |
Acclimation Time (sec) | 1 | 1 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 |
Our sales representatives are here to help you find the right instrument for your application. Fast.